Aideepen 7016A Digital Temperature Controller 30A High-Power Switch 12V/360W/24V/720W/220V/6600W ℃ ℉ Display Heating Cooling NTC Sensor Temp Control Thermostat for Freezer Fridge Hatching

Product selling points: 1. High precision and wide measuring range. 2. The performance is stable and supports long-term use. 3. Has a large and clear display screen to improve readability. 4. Easy to configure. Support °F and °C display. 5. It can control heating and cooling output. parameter: Model: 7016A Material: ABS Voltage: 12v, 24v, 220v (optional) Measuring range: -50℃~110℃ Accuracy: 1℃ Measurement accuracy: ±0.5℃ Sensor: NTC (10K3435) 1m Working temperature: 0℃~50℃ Storage temperature: -10℃~60℃ Product Description: 7016A is a universal single-phase temperature controller, relay output 30A, high power, can control heating/cooling, control temperature can be set arbitrarily between -50~110℃, -58~230', and the temperature difference between start and stop can be in Arbitrarily set 0.1 degree display resolution between 1 and 25 degrees, 1 degree control resolution, delayed start function, 0-30 minutes adjustable, temperature adjustment upper and lower limit range limit function, with data storage function. Function Description: Press the RST key to turn on the thermostat. In the running state, press this key for more than 3 seconds to turn off the thermostat. Refrigeration mode: When the measured temperature value is higher than or equal to the set value + hysteresis, the relay is closed and the output is activated; when the measured temperature is lower than the set value, the relay is disconnected and the output is turned off. Heating mode: When the measured temperature value is higher than or equal to the set value, the relay is disconnected and the output is turned off; when the measured temperature is lower than the set value-hysteresis, the relay is closed to start the output. Hysteresis function: The hysteresis setting limits the maximum interval between on and off. The minimum interval between on and off of this machine is 1°C and the maximum is 15°C. Temperature correction function: When the measured temperature deviates from the standard temperature, use the temperature correction function to make the measured value of the machine consistent with the standard temperature. The corrected temperature = the temperature value before the correction + the correction value (the correction value can be a positive number, Negative numbers and 0) Delay protection function: In the cooling mode, the first power-on, when the measured value is higher than the set value + return difference value, the machine will not immediately start the refrigeration, the machine needs to run the set delay time to start the refrigeration, adjacent two When the second cooling start interval is greater than the delay time, the machine starts cooling immediately. When the interval between two adjacent cooling starts is less than the delay time, the machine needs to run the remaining delay time to start the cooling. The delay time starts from the moment of shutdown, and the delay time for heating mode is the same as for cooling mode. Note: It is recommended that only equipment that uses compressor refrigeration use the delayed start function. Users who do not need the delayed start function, please set this parameter to 0. Upper and lower limit function: The settings of HS and LS limit the setting range of the control temperature point, for example: HS is set to +15, LS is set to -10, the control temperature can only be adjusted between -10 and +15, when the temperature is controlled Press the key again when it is adjusted to -10, the display value will remain at -10 without falling; when the control temperature is adjusted to +15, press the ▲ key again, and the display value will remain at +15 without rising, if the set point needs to be at Outside this range, you must first change the values of HS and LS to achieve. Heating mode: For example, if I want to heat a certain device to 25 degrees and stop, and the temperature drops to 20 degrees to start the heating again, how to change the setting? Setting method: Set the mode to H Set the temperature to 25 degrees and the hysteresis to 5, then when the temperature is higher than or equal to 25 degrees, the relay will be turned off and the output will be turned off. When the temperature is lower than 20 degrees, the relay will be turned on again to start the output Cooling mode: For example, if I want to control a device to stop at 23 degrees and start again at 27 degrees, how to set the cooling change? Setting method Set the mode to C Set the temperature to 27 degrees and the hysteresis to 4, then when the measured temperature is lower than 23 degrees, the relay will be turned off and the output will be turned off. When the temperature is higher than or equal to 27 degrees, the relay will be turned on again to start the output Package list: Digital thermostat1 Sensor1

Aideepen Official Store

Aideepen Official Store

Seller ratings 95%