3.5-Inch Color TFT Hand-held Patient Monitor Human Vital Signs Monitor (SpO2 NIBP ETCO2 TEMP Optional )

"Instructions:The RN100 Series is a multi-functional hand-held patient monitor that can monitor SpO2、Temperature(TEMP)、NIBP、ETCO2、RR、 Pulse rateat(PR)Optional.  This monitor is suitable for adult, pediatric or neonatal patients, and could be.Application:The device is widely applicable to hospital wards, community clinics, Fimily and other medical institutions.Applied in general ward, including, but not limited to, ICU, CCU or ambulance, and so forth.Features:1.Accurate measurement in 0.05% Low perfusion Index, the word leading production in the movement environment. 2.Provide the parameter of PI( Perfusion Index 0.05%-20%). 3.Accurate measurement in all kinds of extreme environment measurement such as neonatal and shock patients. 4.NIBP adopt SAWAA algorithm and SAFD algorithm. SAWAA (Self-Adaptive-Waveform-Amplitude-Adjust) SAFD (Self-Adaptive-Fast-Deflation) 5.Easy operation by 3.5-Inch color TFT. 6.Multiple vital signs measurement parameters for collocation optional.  RN100ST: SpO2+TEMP  RN100: SpO2+NIBP+TEMP  RN100E: SpO2+NIBP+ETCO2+TEMP 7.Two measurements modes: Spot, Monitoring. 8.Data storage capabilities, support for historical data view and trend chart back. In monitoring mode, can continuously record 48 hours of measurement data. In spot mode, 100 users ID, each user can store 200 sets data. 9.Support audio and visual alarm, support to set alarm upper and lower limit values. 10.Lithium ion battery power supply.Technical Specification:1.Oxygen Saturation (%SpO2)  Measure range :SpO2: 0-100%,PR:0-254bpmAccuracy range:SpO2:70-100% ,PR: 30-254bpmMeasurement accuracy:SpO2:ADU(PED): ±2bpm(70-100%) NEO: ±3bpm NEO: ±3bpm On motion condition: ±3bpm,                       PR:ADU(PED): ±3bpm On motion condition: ±5bpm2.TemperatureMeasurement range: 25-45℃ Resolution: 0.1℃ Accuracy: 0.1℃3.NIBP The wider NIBP measurement range      Adult ,PED ,NEO SYS:40~270mmHg, 40~200mmHg ,40~135mmHg  MEAN:20-230mmHg ,20~165mmHg ,20~105mmHg   DIA: 10-210mmHg,10~150mmHg,10~95mmIndependent software protection pressure: 300mmHg ,240mmHg, 150mmHgIndependent hardware protection pressure :320-330mmHg ,265-275mmHg ,160-165mmHg NIBP measurement accuracy: +3mmHg4.CO2 Accuracy, ETCO2 Range ±2mmHg ,  0~40mmHg ±5%mmHg , 41~70mmHg±8%mmHg , 71~100mmHg±10%mmHg, 101~150mmHgPhysical Identity:Product Size:1473cmProduct Weight:0.25kgPackage Size:19.5149.5cmPackage Weight:1.1kg 

Sinohero Medical

Sinohero Medical

Seller ratings 99%

Review

Oops
This video has no reviews.