250V / Alarm • Digital Voltage Meter with Day/Month/Year trackingUse Case: "Check December's voltage graph to prove to your landlord why the fridge died during holiday power surges."4. Self-Healing• Auto-reclose after faults• Memory function for settingsUse Case: "After typhoon blackouts, your lights reboot automatically when power stabilizes."New Voltage Meter FeatureLive Voltage TrackingReal-time display like car dashboardHistorical graphs (24hr/30day/12month)Scenario:"Notice voltage drops every Friday evening? Your meter data helps negotiate with the power company for voltage stabilizers."Why This Matters✓ Dual Protection - Cuts power AND documents voltage issues✓ Preventative Care - Spot problems before appliances fail✓ Evidence Collection - Voltage records for insurance claimsProduct Specifications4 Timer ModesPreset TimerSunrise TimerSunset TimerCycle Timer Over/Under Voltage ProtectionOvervoltage: 100-280V (Options: Disable/Alarm/Trip)Undervoltage: 100-280V (Options: Disable/Alarm/Trip)Advanced SettingsAuto Reclose: Remote control + auto-restart after power failurePower-On Status: Last state/ON/OFFSmart Reclose: Auto-reconnect after voltage issues (Threshold: ±15V from set value)Voltage MeterReal-time displayDay/Month/Year trackingRated voltage (Uimp): 4 kVStatic power: 1 VARated frequency: 50/60 HzRemote operation power: 20 VAOperating Temperature: -25°C to +60°C / -13°F to 140°FReclosing Time Interval: 30s - 30s - 30sReclosing Cycle: 3Electrical Life: 10,000Combination MCB Model (1P+N, 6kA):TOMD6-40Combination RCBO model (1P+N, 6kA, Type A, AC):TOBD6-40,TOBNS-40Combination RCCB model (2P, 4P, AC type, Type A/B):TORD4-63,TORD4B-63,TORE1-63-Can be matched with RCCB,remote switching and splitting of RCCB.-With manual / automatic selector switch.-Work status is indicated by LED.-Automatic switch on distribution board when electric trip happen-Auto reclosing interval time : 10 second > 60second > 300secondTechnical Data OF RCCB RECLOSERThis product has no over-current protection function, please use it with MCBTip: Please noted the input MUST from TOP side, or will damage the product.Tips: 30mA, 100mA, 300mA is electromechanical type, 10mA is electronic type.The default voltage is 220V~250V. If you need 110V voltage, please contact customer service, item needs to be customized.GeneralThis is A Type Residual Current Circuit BreakerThe RCCB provides indirect protection to the operator’s body under such condition that the exposed live parts should be connected to a proper earthing pole.The RCCB also provides protection against the fire danger caused by earth fault current due to function failure of over-current protection device.Special tips:1. RCCB with rated sensitivity up to 10mA could be used as supplementary protecting device in case otherprotecting device fails its protection against electric shock.2. RCCB designed for household installation and other similar application, is for non-professional operation,and no maintenance is required.3. RCCB provides on protection against electric shock resulted from direct contacts of both protected lines,or leakage current between these two lines.4. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to RCCB as precaution against potential surge voltage and current occurring at its power input side.5. Satisfying conditions and applications as mentioned above,RCCB with “ON-OFF” indicating device is considered suitable for isolation function.">Tuya Wifi Auto Recloser 2P Type A RCD RCCB 6KA 16A 63A 30mA 230V WiFi Smart Circuit Breaker with Over/Under Voltage Protection

Tuya Wifi Auto Recloser 2P Type A RCD RCCB 6KA 16A 63A 30mA 230V WiFi Smart Circuit Breaker with Over/Under Voltage Protection

About the Trademark Upgrade:To address any concerns regarding our logo update, Changyou Technology (Zhejiang) Co., Ltd. has legally registered the EU trademarks tongou (Registration No.: 018630309) and Chayo (Registration No.: 019312969).This logo update is merely a visual upgrade and shall not affect the ownership, validity or exclusive right to use of the aforesaid trademarks. In addition, it will not have any impact on product quality, performance, specifications, after-sales service or business cooperation.All products and services remain consistent and reliable as always.FAQ:Q1: Failure to reclose automatically?A: Please follow these steps to troubleshoot:Ensure the device is in Wi-Fi mode (slide the switch to the right for Wi-Fi mode). The autoreclose function is only available in Wi-Fi mode.Please make sure the "Auto Reclose" function is enabled within the Tuya app.Q2: Product cannot be manually tripped (handle stuck)?A: Please try performing a remote open/close operation via the App. This should resolve the issue.Q3: Product fails to reclose automatically, and the display shows error codes C01, H01, or H02?A:The product's instruction manual contains detailed explanations for these error codes. First, please go to "Setting → Advanced → Fault Reset" in the App to clear the fault codes. Then, try power cycling the device (turn power off and on again). This should resolve the fault.Please note:In case of unwanted tripping after an electrical fault (earth leakage current )(This Link is WiFi TOSAR type AUTO RECLOSER matched with Type A RCD)ApplicationsRCCB+RECLOSER can automatically reclose when RCCB trips unexpectedly, no need for manual closing, reduce the cost of manual maintenance, and eliminate faults in time to improve efficiency. Can be widely used in power grid terminal line, such as meter box, new energy circuit management, PV solar control box, smart electricity, smart home, new energy vehicle charging pile, and so on.When the device is in remote mode, the 30-30-30 automatic closing logic will be disabled.Function Features of WiFi recloser (RCD)1. Anywhere Control• Works with both Tuya & Smart Life APP• Remote ON/OFF + Real-time voltage monitoringUse Case: "During storms, receive instant alerts when voltage exceeds 250V and cut power remotely from your office."2. Smart Scheduling• Sunrise/Sunset automation• Custom cycles (15min-24hr)Use Case: "Set your aquarium pump to run 15min every 2hrs while vacationing in Bali."3. Voltage Protection + Live Meter• Auto shutdown >250V / Alarm • Digital Voltage Meter with Day/Month/Year trackingUse Case: "Check December's voltage graph to prove to your landlord why the fridge died during holiday power surges."4. Self-Healing• Auto-reclose after faults• Memory function for settingsUse Case: "After typhoon blackouts, your lights reboot automatically when power stabilizes."New Voltage Meter FeatureLive Voltage TrackingReal-time display like car dashboardHistorical graphs (24hr/30day/12month)Scenario:"Notice voltage drops every Friday evening? Your meter data helps negotiate with the power company for voltage stabilizers."Why This Matters✓ Dual Protection - Cuts power AND documents voltage issues✓ Preventative Care - Spot problems before appliances fail✓ Evidence Collection - Voltage records for insurance claimsProduct Specifications4 Timer ModesPreset TimerSunrise TimerSunset TimerCycle Timer Over/Under Voltage ProtectionOvervoltage: 100-280V (Options: Disable/Alarm/Trip)Undervoltage: 100-280V (Options: Disable/Alarm/Trip)Advanced SettingsAuto Reclose: Remote control + auto-restart after power failurePower-On Status: Last state/ON/OFFSmart Reclose: Auto-reconnect after voltage issues (Threshold: ±15V from set value)Voltage MeterReal-time displayDay/Month/Year trackingRated voltage (Uimp): 4 kVStatic power: 1 VARated frequency: 50/60 HzRemote operation power: 20 VAOperating Temperature: -25°C to +60°C / -13°F to 140°FReclosing Time Interval: 30s - 30s - 30sReclosing Cycle: 3Electrical Life: 10,000Combination MCB Model (1P+N, 6kA):TOMD6-40Combination RCBO model (1P+N, 6kA, Type A, AC):TOBD6-40,TOBNS-40Combination RCCB model (2P, 4P, AC type, Type A/B):TORD4-63,TORD4B-63,TORE1-63-Can be matched with RCCB,remote switching and splitting of RCCB.-With manual / automatic selector switch.-Work status is indicated by LED.-Automatic switch on distribution board when electric trip happen-Auto reclosing interval time : 10 second > 60second > 300secondTechnical Data OF RCCB RECLOSERThis product has no over-current protection function, please use it with MCBTip: Please noted the input MUST from TOP side, or will damage the product.Tips: 30mA, 100mA, 300mA is electromechanical type, 10mA is electronic type.The default voltage is 220V~250V. If you need 110V voltage, please contact customer service, item needs to be customized.GeneralThis is A Type Residual Current Circuit BreakerThe RCCB provides indirect protection to the operator’s body under such condition that the exposed live parts should be connected to a proper earthing pole.The RCCB also provides protection against the fire danger caused by earth fault current due to function failure of over-current protection device.Special tips:1. RCCB with rated sensitivity up to 10mA could be used as supplementary protecting device in case otherprotecting device fails its protection against electric shock.2. RCCB designed for household installation and other similar application, is for non-professional operation,and no maintenance is required.3. RCCB provides on protection against electric shock resulted from direct contacts of both protected lines,or leakage current between these two lines.4. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to RCCB as precaution against potential surge voltage and current occurring at its power input side.5. Satisfying conditions and applications as mentioned above,RCCB with “ON-OFF” indicating device is considered suitable for isolation function.

Prime Supply_Play Life

Prime Supply_Play Life

Seller ratings 95%

Review

Oops
This video has no reviews.